HumaLoop T

Molecular DXLAMPInstrumentsIsothermal Amplification

    Price per unit:

    XXX,XX € asterisk icon

    Detect TB more accurately and easily with TB-LAMP

    HumaLoop T is a semi-automated incubator and fluorescence analyzer, using Loop-mediated isothermal amplification (LAMP). HumaLoop T allows the qualitative detection of bacteria belonging to the Mycobacterium Tuberculosis Complex (MTBC) in human sputum samples. The application is simplified by consolidated processing: sample lysis, amplification and detection are performed on a single instrument. Preinstalled incubation times and temperatures as well as easy interpretable results by visual reading of green fluorescence make HumaLoop T the ideal tool for the molecular screening of pathogens in peripheral laboratories.
    feature icon

    Throughput:

    Up to 16 tests per run or up to 70 samples per day
    feature icon

    Time to result

    Results in 1 – 2 hours depending on sample number
    feature icon

    Incubation

    Preinstalled incubation times and temperatures for LoopampTM MTBC assays
    feature icon

    Processing

    Sample preparation, amplification and detection on a single instrument
    feature icon

    Result interpretation

    Visual reading of fluorescence signals
    feature icon

    Portable battery system

    LAMP devices can be operated up to three runs
    feature icon

    Technology

    Loop-mediated isothermal amplification (LAMP)

    Easy-to-use molecular TB detection for primary and peripheral laboratories

    Specially designed as a consolidated platform for
    sample preparation, amplification and easy visual
    result reading, HumaLoop T facilitates sensitive
    and reliable detection of tuberculosis with the
    LoopampTM MTBC Detection Kit.

    TB-LAMP is robust and easy to perform

    Advanced molecular detection in 4 easy steps. Reagent storage and shipment at room temperature as well as the excellent test performance make molecular pathogen testing available in rural areas with limited settings.

    Convenient and easy result reading

    Insert the tubes into the detection unit and turn the UV light on. Positive results light green, negative results show no fluorescence.

    Perfect for use in remote areas

    Portable and independent from mains with HUMANs power solution by solar panel and battery system.

    Detect TB. Accurately. Easily.

      Smear microscopy misses nearly every second positive TB case.
    • TB-LAMP detects > 15 % more positive TB cases
    • Is also applicable to confirm smear negative results
    • Can be used as first line test for all patient groups when the GeneXpert system is not available
    • WHO recommends TB-LAMP as an alternative for smear microscopy.

    Techspecs

    Analyzer type

    Loopamp™ incubator with fluorescence detection unit

    Reagent system

    Closed

    Tests per run

    16

    Measuring mode

    Fluorescence detection

    Test method

    Loop-mediated isothermal amplification

    # of programmable tests

    1

    Sample type

    Sputum (native or NALC-treated)

    Test positions

    16

    Wavelengths

    450~500 nm (465~470 nm)

    Physical dimensions (W x D x H)

    Instrument: 25 x 30.6 x 18.2 cm
    Weight: 9.5 kg

    Environmental

    Operating temperature 5…40°C, relative humidity 30…80 % (non condensing)
    Transport temperature -5…40°C, relative humidity 20…85% (non condensing)
    Altitude Up to 3,800 m

    We’ve helped hundreds of global companies

    We’ve helped hundreds of global companies

    • Anderson Mugendi & Simon Chege
      testimonial flag Kenya

      “We love using the new TB-LAMP technology: it is very quick and only takes about two hours for 14 samples per run. Thus a patient gets clarity on the same day whether he has TB or not. TB-LAMP provides very reliable results with a high sensitivity and specificity. Lastly, the HumaLoop T is a simple small machine which requires little infrastructure.”

      Kangemi Health Center - Kenya

      Anderson Mugendi & Simon Chege

    • Anupam Kumar
      testimonial flag India

      “The high sensitivity, high throughput and the reliability of the assay, even under the challenging climate conditions, have convinced us. With this novel technology, we have the opportunity to find more tuberculosis cases than with traditional methods.”

      Dr. Lal PathLabs - India

      Anupam Kumar

    • Chinyere Obiejemba
      testimonial flag Nigeria

      “TB-LAMP is a DNA-based method for quick TB diagnosis. It is fast, specific and has replaced microscopy because of its built-in heating block and UV light for reading sample results. It can be used in the remotest places because it's portable.”

      EpiConsult Clinic & Diagnostic Centre Ltd. - Nigeria

      Chinyere Obiejemba

    • Joel Wepngong Tabah
      testimonial flag Cameroon

      “When I attended the training, I understood that TB-LAMP is beneficial for patients and technicians. Previously, the patient's first and second sputum was used in microscopy, but now, with the sensitivity of TB-LAMP, you only need to take the sputum once. With microscopy, it was difficult to handle 50 samples per day. This technique allows us to test 14 patients in one run and up to 70 in one day. For me, TB-LAMP is the best method for rapid detection of tuberculosis.”

      Baptist Hospital Mutengene - Cameroon

      Joel Wepngong Tabah

    • Prof. Dr. Shirin Tarafder
      testimonial flag Bangladesh

      “Since 2016, WHO recommended TB-LAMP assay as a rapid molecular diagnostic test for rapid detection of tuberculosis and as a replacement of microscopy in resource poor settings and hard to reach areas. TB-LAMP takes about 1- 2 hours for 14 samples per run and up to 70 in one day. TB-LAMP provides very reliable results with high sensitivity and specificity as well as requires little infrastructure.”

      Department of Microbiology & Immunology Dean ,Faculty of Basic & Paraclinical Science Bangabandhu Sh - Bangladesh

      Prof. Dr. Shirin Tarafder

    • Tiago TxaVunda
      testimonial flag Angola

      “I like the HumaLoop T and the easy handling very much. As a journey from the capital Luanda to my lab takes about 3 days by road, it is especially important for us to have a reliable device that requires only a minimum service every 12 months.”

      HSC Nzagi - Angola

      Tiago TxaVunda

      Downloads

      GDF_Catalog_2020-03_EN.pdf
      Compilation

      GDF_Catalog_2020-03_EN.pdf

      • Language:
        EN
      981014_Flyer_TB-LAMP_ES.PDF
      Flyer

      981014_Flyer_TB-LAMP_ES.PDF

      • Language:
        ES
      981014_Flyer_TB-LAMP_FR.PDF
      Flyer

      981014_Flyer_TB-LAMP_FR.PDF

      • Language:
        FR
      Flyer_TB-LAMP_LessonsLearned_EN.pdf
      Flyer

      Flyer_TB-LAMP_LessonsLearned_EN.pdf

      • Language:
        EN
      981014_Flyer_TB-LAMP_EN.PDF
      Flyer

      981014_Flyer_TB-LAMP_EN.PDF

      • Language:
        EN
      981014-5_Poster_TB-LAMPWorkflow_2018-07_EN.PDF
      Poster

      981014-5_Poster_TB-LAMPWorkflow_2018-07_EN.PDF

      • Language:
        EN
      981014-5_Poster_TB-LAMPWorkflow_2018-07_ES.PDF
      Poster

      981014-5_Poster_TB-LAMPWorkflow_2018-07_ES.PDF

      • Language:
        ES
      981014-5_Poster_TB-LAMPWorkflow_2018-07_FR.PDF
      Poster

      981014-5_Poster_TB-LAMPWorkflow_2018-07_FR.PDF

      • Language:
        FR
      file icon
      Presentation

      Presentation_TB-LAMP_2017-04_EN.PPTX

      • Language:
        EN
      981261_ProducatCard_HumaLoopT_M_print_2019-03_EN.PDF
      Product Information Card

      981261_ProducatCard_HumaLoopT_M_print_2019-03_EN.PDF

      • Language:
        EN
      981261_ProducatCard_HumaLoopT_M_view_2019-03_EN.PDF
      Product Information Card

      981261_ProducatCard_HumaLoopT_M_view_2019-03_EN.PDF

      • Language:
        EN
      981017-2_PublicationList_TB-LAMP_EN.PDF
      Publication

      981017-2_PublicationList_TB-LAMP_EN.PDF

      • Language:
        EN

      Associated Products

      Need help finding instrument?

      We will gladly assist you in making the right decision to achieve your business goals

      message question circle icon Get a consultation
      Need help finding instrument?